Agitator Design Calculation: Motor Power, Torque & Impeller Sizing

An agitator design calculation Excel worksheet should connect impeller geometry, rotational speed, liquid properties, absorbed power, and shaft torque. For a selected impeller, calculate mixing Reynolds number, obtain the applicable power number, and use P = NpρN³D⁵. Then calculate running torque and account for transmission losses before screening a motor.

This guide works through a single-impeller blending example. A 0.60 m impeller at 180 rpm draws an estimated 2.73 kW and develops 144.8 N·m of hydrodynamic running torque. With an illustrative 90% mechanical transmission efficiency and 25% power allowance, the motor-output screening requirement becomes 3.79 kW.

These calculations estimate load; they do not prove blending time, solids suspension, dispersion quality, or mechanical suitability. The power number and operating assumptions must match the actual impeller and vessel.

Start with the mixing objective

Agitator design begins with the process result required, rather than a motor rating. A blend tank may need a specified concentration uniformity within a given time. A slurry vessel may need off-bottom suspension. A gas–liquid reactor may need mass-transfer performance. Each objective can favor a different impeller, speed, clearance, or number of impellers.

Duty Key design questions
Liquid blending What mixing time and uniformity are required? Are the liquids miscible?
Solids suspension What particle sizes, densities, loading, and suspension criterion apply?
Gas dispersion What gas rate and mass-transfer target apply? Is flooding possible?
Heat transfer What circulation is needed near the jacket, coils, or heat-transfer surface?
Viscous processing How does rheology change with shear, temperature, and batch progress?

For an overview of equipment options, see our agitator types and applications guide. Treat fluid allocation, tank internals, baffles, and feed location as part of the mixing system.

Essential agitator design equations

Use rotational speed in revolutions per second in the power and Reynolds-number equations:

N = n/60, where n is rpm.

Remix = ρND²/μ

Pimpeller = NpρN³D⁵

τ = Pimpeller/(2πN)

Tip speed = πDN

Symbol Meaning SI unit
ρ Liquid density kg/m³
μ Dynamic viscosity Pa·s
D Impeller diameter m
N Impeller rotational frequency s⁻¹, revolutions per second
Np Power number Dimensionless
P Power transferred by the impeller to the liquid W
τ Hydrodynamic torque at impeller speed N·m

The units of ρN³D⁵ reduce to kg·m²/s³, or watts. Entering rpm directly in place of N would multiply the calculated power by 60³, making the result unusable.

The manufacturer’s SPX FLOW Lightnin mixing-technology brochure presents power, pumping, and impeller Reynolds-number relationships. Its emphasis on both power and flow performance is useful: equal power does not guarantee equal mixing performance.

Power number is an input that needs evidence

Np depends on impeller geometry and the operating flow regime, as well as relevant vessel conditions. Blade count, blade angle, diameter ratio, bottom clearance, baffling, and interactions with other impellers can matter. A generic label such as “pitched-blade turbine” is not sufficient to establish a final design value.

Use a vendor curve or a suitable published correlation for the actual arrangement. In an appropriate fully turbulent regime, the curve may approach a nearly constant power number. In laminar mixing, a relation of the form Np = K/Re may apply for a particular geometry; substitution gives P = KμN²D³. The constant K must come from relevant data.

Do not reuse pipe-flow Reynolds thresholds for a mixing tank. Nor should a single viscosity value be treated as proof of turbulence. The Sumitomo Heavy Industries mixing discussion explains why the Np–Re relationship matters when interpreting changes in power and flow.

The example below assumes Np = 1.30 is applicable at the calculated Reynolds number for the selected baffled arrangement. It is an illustrative coefficient, not certified performance data for a named impeller.

Worked example: blending a Newtonian liquid

Consider a vertical, baffled tank containing a single Newtonian liquid. The trial design uses one submerged impeller and no gas sparging. Density and viscosity are treated as constant, and the operating objective is bulk blending. No blend-time guarantee is assigned.

Input Illustrative value
Tank inside diameter T 1.80 m
Cylindrical liquid height H 1.80 m
Impeller diameter D 0.60 m
Impeller speed n 180 rpm
Liquid density ρ 1,000 kg/m³
Dynamic viscosity μ 0.010 Pa·s = 10 cP
Assumed applicable power number 1.30
Mechanical transmission efficiency ηmech 0.90
Illustrative power allowance multiplier M 1.25

The cylindrical volume excludes dished-head volume and internals displacement. Use actual working volume for a real vessel. The trial ratio D/T = 0.333 is a geometry choice for this example, not a universal impeller-sizing rule.

Step 1: Calculate volume and speed

V = πT²H/4 = π × 1.80² × 1.80/4 = 4.580 m³

N = 180/60 = 3.00 s⁻¹

Use the agitator output speed after the gearbox. The motor rotor speed is generally different and must not be substituted into the impeller equations.

Step 2: Calculate impeller Reynolds number

Remix = 1000 × 3.00 × 0.60²/0.010 = 108,000

This is consistent with using a turbulent-region coefficient for many conventional baffled impellers, but the selected impeller’s curve remains the basis for accepting Np = 1.30. If viscosity rises during the batch, recalculate Reynolds number and revisit the coefficient.

Step 3: Calculate absorbed impeller power

P = 1.30 × 1000 × 3.00³ × 0.60⁵ = 2729.38 W = 2.729 kW

This is the estimated power delivered to the liquid by the impeller. It excludes losses upstream of the impeller and is not the same as the electrical power measured at the motor supply.

Step 4: Calculate running torque and tip speed

τ = 2729.38/(2π × 3.00) = 144.8 N·m

An equivalent practical expression is τ ≈ 9550 × P(kW)/n(rpm). Use power and speed at the same shaft location.

Tip speed = π × 0.60 × 3.00 = 5.655 m/s

Tip speed can help compare mechanical and shear-related operating conditions. It does not independently predict local shear rate, droplet size, or damage to a shear-sensitive product.

Step 5: Calculate power per working volume

P/V = 2.729/4.580 = 0.596 kW/m³

Record this as a comparison metric, not an acceptance limit. A tank can have adequate average power per volume and still contain stagnant regions or fail to suspend solids because the circulation pattern is unsuitable.

From impeller power to motor and gearbox selection

For this screening calculation, the assumed 90% mechanical efficiency represents the aggregate running losses between motor output and the liquid-driving impeller. Its value must be replaced by an appropriate drive-loss estimate. If gearbox losses and seal losses are modeled separately, do not count them again inside the efficiency.

Required motor mechanical output = M × Pimpeller/ηmech

Required output = 1.25 × 2.729/0.90 = 3.791 kW

A nominal 4 kW motor is therefore a candidate for further review, not an approved selection. Confirm available rating, duty, voltage, ambient conditions, hazardous-area requirements where relevant, VFD operation, and the actual speed–torque capability.

The corresponding allowance-adjusted hydrodynamic torque is 1.25 × 144.8 = 181.0 N·m. At 180 rpm, a 4 kW motor with the assumed mechanical transmission efficiency could deliver about 191.0 N·m to the impeller at rated motor output. That does not establish the gearbox’s permissible continuous or peak output torque.

The 1.25 multiplier is merely an example power allowance. It is not a calculated startup factor, a motor nameplate service factor, or a manufacturer-approved gearbox service factor. SEW-EURODRIVE’s service-factor guidance notes that the relevant determination depends on the manufacturer’s method and catalog data.

Motor efficiency is needed separately for electrical input. If an illustrative motor efficiency were 92% at the operating point, normal electrical input would be approximately 2.729/(0.90 × 0.92) = 3.296 kW, excluding VFD losses. Do not compare that electrical input directly with a motor rating specified as mechanical output.

Startup torque and mechanical integrity

Agitator component overview listing the drive assembly, motor, shaft, impellers, bearings, coupling and seals
Agitator components to consider during drive and mechanical review. This overview is not a dimensional design drawing.

Running power does not resolve breakaway or acceleration torque. A simplified shaft-referred balance includes load torque, friction, and inertial torque:

τrequired = τload + τfriction + Jequivalentα

Refer every term to the same shaft, applying gearbox ratio and efficiency consistently. Cold viscous material, settled solids, or yield-stress behavior can create loads that the steady Newtonian example does not represent. At zero speed, the running relation P/(2πN) cannot be used to infer breakaway torque.

The Oriental Motor sizing guidance identifies inertia, torque, speed, and acceleration capability as separate selection checks. For an industrial agitator, also obtain the mixing vendor’s load cases and gearbox manufacturer’s continuous and peak ratings.

Shaft diameter cannot be finalized from torsion alone. Evaluate bending from hydraulic forces, fatigue, stress concentrations, bearing loads, critical speeds, deflection at the seal, impeller attachment, and mounting loads. VFD speed changes may cross a mechanical resonance even when motor power remains acceptable.

Impeller sizing: geometry and available power

One useful screening rearrangement is:

D = [Pallowable,impeller/(NpρN³)]1/5

For the candidate 4 kW motor, retaining the example efficiency and allowance:

Pallowable,impeller = 4000 × 0.90/1.25 = 2880 W

D = [2880/(1.30 × 1000 × 3³)]1/5 = 0.6065 m

This is a power-budget diameter, not the required mixing diameter. The selected impeller must also satisfy circulation, submergence, bottom clearance, tank geometry, and process performance. Changing D/T may change Np, so the rearrangement is only valid while the assumed coefficient remains applicable.

For solids handling, review our agitator design guide for preventing solids settling. A power-budget diameter cannot establish just-suspended speed without particle and geometry information.

Build the agitator calculation in Excel

Use column A for labels, B for inputs or formulas, and C for units. Keep the power-number source and its validity range in a visible note. These formulas use English function names and comma separators.

Cell Input Value
B2 Tank diameter, m 1.8
B3 Cylindrical liquid height, m 1.8
B4 Impeller diameter, m 0.6
B5 Impeller speed, rpm 180
B6 Density, kg/m³ 1000
B7 Dynamic viscosity, Pa·s 0.010
B8 Applicable power number 1.30
B9 Mechanical efficiency 0.90
B10 Illustrative power allowance multiplier 1.25
B11 Candidate motor mechanical rating, kW 4
Cell Output Excel formula
B14 Working volume, m³ =PI()*B2^2*B3/4
B15 Speed, rev/s =B5/60
B16 D/T =B4/B2
B17 Mixing Reynolds number =B6*B15*B4^2/B7
B18 Impeller power, W =B8*B6*B15^3*B4^5
B19 Impeller power, kW =B18/1000
B20 Running hydrodynamic torque, N·m =B18/(2*PI()*B15)
B21 Tip speed, m/s =PI()*B4*B15
B22 Power per volume, kW/m³ =B19/B14
B23 Screening motor-output requirement, kW =B19*B10/B9
B24 Power-budget diameter, m =((B11*1000*B9/B10)/(B8*B6*B15^3))^(1/5)
B25 Candidate power check =IF(B11>=B23,"Meets power screen only","Below power screen")

Require positive dimensions, speed, density, viscosity, power number, and motor rating; constrain efficiency to greater than zero and no more than one. Use an allowance multiplier of at least one for this screening method. Check D < T and confirm actual impeller clearance and submergence separately.

The sheet does not automatically select Np or certify a flow regime. Recalculate using a suitable correlation whenever speed, viscosity, or geometry changes. A zero-speed case requires separate logic for startup analysis. This article supplies a worksheet layout and formulas, not a newly generated Excel download.

Check speed and diameter sensitivity

The following results retain density = 1,000 kg/m³ and Np = 1.30. They are conditional comparisons under that constant-power-number assumption.

Speed, rpm Diameter, m Power, kW Running torque, N·m Motor-output screen, kW
150 0.60 1.580 100.6 2.194
180 0.60 2.729 144.8 3.791
210 0.60 4.334 197.1 6.020
180 0.66 4.396 233.2 6.105

At constant diameter and power number, power varies with speed cubed and torque with speed squared. Increasing diameter by 10% increases calculated power by 1.1⁵ = 1.6105, or about 61%. The candidate 4 kW motor does not meet the example power screen for either the 210 rpm case or the 0.66 m impeller case.

Reducing speed may reduce power but also reduce circulation and mixing performance. When comparing scale-up options, constant tip speed, constant power per volume, and constant Reynolds number are different constraints. No single one automatically preserves all process outcomes.

When this simplified model needs extending

Multiple impellers require interaction and spacing review; adding isolated-impeller power values is only an approximation unless supported by data. Gas sparging can alter power draw and flow patterns. Non-Newtonian fluids require a rheology-aware approach rather than an arbitrary constant viscosity.

If impeller pumping capacity is needed, a suitable flow-number relationship is Qp = NqND³. Obtain Nq for the actual geometry. Tank volume divided by pumping rate is a nominal circulation timescale, not a guaranteed blend time.

Investigate unexpected motor current alongside measured speed, density, viscosity, liquid level, and mechanical condition. High current can indicate increased process load or mechanical drag. Low absorbed power can coexist with poor mixing caused by inadequate immersion, vortexing, gas effects, or damaged blades.

Frequently asked questions

1. What is the main agitator power formula?

P = NpρN³D⁵, with N in revolutions per second and D in metres. Select the power number from data applicable to the impeller, flow regime, and tank arrangement.

2. How do I calculate agitator torque from kW and rpm?

Running torque in N·m is approximately 9550 × power in kW divided by rpm. Use power and speed at the same shaft location; startup torque requires a separate assessment.

3. Can I choose the motor directly from impeller power?

No. Account for mechanical losses and the specified operating envelope, then check startup, acceleration, gearbox ratings, motor duty, and speed–torque capability.

4. Is D/T = one-third always correct?

No. It is a trial ratio in this example. Impeller type, process objective, clearance, liquid level, and circulation requirements determine suitable geometry.

5. Can a constant power number be used for viscous liquids?

Only where the applicable Np–Re data supports it. Laminar and transitional operation generally require a Reynolds-dependent correlation, with additional treatment for non-Newtonian rheology.

6. Does sufficient power guarantee solids suspension?

No. Particle properties, solids loading, impeller position, flow pattern, and the required suspension criterion must also be evaluated.

7. Does this Excel calculation determine shaft diameter?

No. It estimates hydrodynamic running load. Shaft design also needs bending, fatigue, deflection, critical-speed, attachment, seal, and bearing checks.

Use the worksheet to document assumptions and compare options

The example produces 2.73 kW of impeller power, 144.8 N·m of running torque, and a 3.79 kW motor-output screening requirement. Carry those results into a process-performance and mechanical review rather than treating them as a complete equipment selection. Explore more engineering calculation guides at GrowMechanical.