Condensate Flow & Flash Steam Calculator

Condensate Flow & Flash Steam Calculator | GrowMechanical

Condensate Flow & Flash Steam Calculator | GrowMechanical

Compute flash steam fraction, flash steam rate, and remaining condensate after a pressure drop.

Inputs

kg/h
Plant gauges are usually in bar g. Absolute = gauge + 1.013.
bar g
bar g
Formula: x = (h₁ − hf2)/hfg2, limited to 0–1. Then ṁflash = x·ṁ₁ and ṁcond,out = (1−x)·ṁ₁.

Results

Results will appear here…

Tip: Ensure P₁ > P₂ so flashing can occur. If subcooled, a small ΔT can eliminate flashing.


Method & Assumptions

  • Saturation properties via built-in mini steam table (0.5–20 bar(a)) with linear interpolation.
  • Subcooled h₁ ≈ hf(P₁) − Cp·(Tsat,P1 − Tcond), with Cp=4.19 kJ/kg·K.
  • If (h₁ − hf2) ≤ 0 ⇒ no flash steam (x = 0). If P₁≤P₂, flashing is not possible.
Engineering judgement required. For contractual work, validate with full steam tables or your plant standard.

© GrowMechanical — Process & Utility tools for engineers.

Advertisements
Select your currency
INR Indian rupee